Specification of Fluke 115 True-RMS AC/DC Digital Multimeter
Fluke 115 Field Service Technicians Multimeter
- Fluke 115 True-RMS AC/DC Digital Multimeter
- Resistance, continuity, frequency, capacitance, and diode test
- Measures 20 A (30 seconds momentary; 10 A continuous)
- Large white LED backlight to work in poorly lit areas
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak)
- True-rms for accurate measurements on non-linear loads
- Min/Max/Average with elapsed time to record signal fluctuations
- CAT III 600 V safety rated
- True RMS
- .5% Accuracy
- 28% larger digits
- 6000 counts
- Bargraph
- Backlight
- Min-max recording
Designed by electricians. Engineered by Fluke.
A Compact true-rms meter ideal for field service technicians. The Fluke 115 is the solution for a wide variety of electrical and electronic testing applications. This true-rms meter provides easy one-handed operation in a compact package.
Specs
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 95 %.
The accuracy specifications take the form of: ± ( [ % of Reading ] + [ Counts ] )
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display Digital: 6,000 counts, updates 4/sec
Bar graph 33 segments, updates 32/sec
Operating temperature -10 °C to + 50 °C
Storage temperature -40 °C to + 60 °C
Battery 9 volt Alkaline, NEDA 1604A/IEC 6LR61
Battery life 400 hours typical, without backlight
Measurement | Range | Resolution | Accuracy ± ([% of reading] + [counts]) |
DC millivolts | 600.0 mV | 0.1 mV | 2.0 % + 3 |
DC volts | 6.000 V | 0.001 V | |
60.00 V | 0.01 V |
600.0 V | 0.1 V |
Auto volts | 600.0 V | 0.1 V | 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) |
AC millivolts1 true-rms | 600.0 mV | 0.1 mV | 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
AC volts1 true-rms | 6.000 V | 0.001 V | 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
60.00 V | 0.01 V |
600.0 V | 0.1 V |
Continuity | 600 Ω | 1 Ω | Beeper on < 20 Ω, off> 250Ω; detects opens or shorts of 500 µs or longer. |
Ohms | 600.0 Ω | 0.1 Ω | 0.9 % + 2 |
6.000 kΩ | 0.001 kΩ | 0.9 % + 1 |
60.00 kΩ | 0.01 kΩ |
600.0 kΩ | 0.1 kΩ |
6.000 MΩ | 0.001 MΩ |
40.00 MΩ | 0.01 MΩ | 1.5 % + 2 |
Diode test | 2.000 V | 0.001 V | 0.9 % + 2 |
Capacitance | 1000 nF | 1 nF | 1.9 % + 2 |
10.00 µF | 0.01 µF |
100.0 µF | 0.1 µF |
9999 µF | 1 µF | |
100 µF to 1000 µF | | 1.9 % + 2 |
> 1000 µF | | 5 % + 20 |
Lo-Z capacitance | 1 nF to 500 µF | | 10 % + 2 typical |
AC amps true-rms (45 Hz to 500 Hz) | 6.000 A | 0.001 A | 1.5 % + 3 |
10.00 A | 0.01 A |
20 A continuous overload for 30 seconds max. |
DC amps | 6.000 A | 0.001 A | 1.0 % + 3 |
10.00 A | 0.01 A |
20 A continuous overload for 30 seconds max. |
Hz (V or A input) 2 | 99.99 Hz | 0.01 Hz | 0.1 % + 2 |
999.9 Hz | 0.1 Hz |
9.999 kHz | 0.001 kHz |
50.00 kHz | 0.01 kHz |
In The Box
- Fluke TL75 Test leads
- Holster
- User’s Manual
- 9 V battery (installed)