Specification of

Description

Oxidation Pressure Vessel Precision machined stainless steel pressure vessel includes threaded body; lid; stem with filler rod and mounting flange; needle valve for purging, pressurizing and exhausting pressure vessel with oxygen; and burst disk assembly. Pressure vessel interior and inside of stem have a high polish to facilitate cleaning and prevent corrosion. Stainless steel burst disk ruptures at 223psi (1537kPa) to prevent unsafe pressure build-up inside pressure vessel. Octagonal sections on the pressure vessel and lid permit tight closure with wrench. Includes buna-N gaskets. 

Test Method

Provides an indication of the tendency of gasoline and aviation fuels to form gum in storage. The sample is oxidized inside a stainless steel pressure vessel initially charged with oxygen at 100psi (689kPa) and heated in a boiling water bath. The amount of time required for a specified drop in pressure (gasoline) or the amount of gum and precipitate formed after a specific aging period (aviation fuels) is determined.

Specification

Conforms to the specifications of: ASTM D525, D873; IP 40, IP 138; ISO 7536; 

DIN 51780, 51799; FTM 791-3352, 791-3354; NF M 07-012, 07-013

Maximum Temperature:

Solid Block Baths: 250°F (121°C)
2 Unit Water/Liquid Bath: boiling water
6 Unit Water/Liquid Bath: 250°F (121°C)

Power:

Solid Block Baths: 0-1300W or 0-2500W
2 Unit Water/Liquid Bath: 0-2000W
6 Unit Water/Liquid Bath: 0-3000W

Features

  • Oxidation Stability Test Apparatus
  • Conforms to ASTM D525, D873, ISO 7536 and related specifications
  • Oxidata® Pressure Measurement System
  • Available in two, four or six-unit configurations
  • Choice of water/liquid or solid block heating baths
  • Oxidation pressure vessel incorporates burst disk assembly
  • Water/Liquid Oxidation Baths
  • Water/liquid baths conforming to ASTM and related specifications.
  • Constant temperature baths for heating K10500 Oxidation Pressure
  • Vessels in accordance with ASTM specifications.
  • Solid Block Oxidation Baths
  • Solid block baths conforming to ASTM and related specifications.
  • Constant temperature baths for heating K10500 Oxidation Pressure
  • Vessels in accordance with ASTM specifications.
  • Mechanical Pressure Measuring and Recording Equipment
  • One-pen or two-pen mechanical recorders
  • Pressure gauge for aviation fuel tests
  • Oxidata® Pressure Measurement Systems
  •  Electronic pressure measurement systems exclusively designed for ASTM oxidation test methods
  • Powerful Oxidata® software for Windows® environments
  • Monitors up to twelve pressure and four temperature channels
  • Automatic end-point detection
  • Real-time average bath temperature display
  • Can be installed to most manufacturer's fuels oxidation test apparatus

Additional Accessories

  • K10500 Oxidation Pressure Vessel
  • K10540 Glass Sample Container and Cover with pour out spout
  • K10540/C Glass Sample Container Cover Only
  • K10510 Gasket. Replacement composition gasket for
  • K10500 Oxidation Pressure Vessel
  • K10551 Pressure Line. For pressurizing Oxidation Pressure Vessel. 6 ft. (1.83m) long, with quick release coupling for needle valve on pressure vessel and threaded fitting for oxygen tank
  • K10556 Oxygen Manifold Pressure Relief System - Connects to oxygen source to prevent overcharging of vessel. Equipped with relief valve to vent at 125psi and 300 series stainless steel 150psi burst disk assembly. Constructed from 300 series stainless steel. Cleaned for oxygen service
  • K10520 Wrench. For tightening seal on Oxidation Pressure Vessel
  • K10530 Table Socket. Installs in benchtop to aid in tightening seal on Oxidation Pressure Vessel
  • K10560 Bronze Tubing - For connecting pressure recorder to vessel. Flexible seamless helical tubing with protective armor braid and connections. 5 ft (1.52m) long
  • K10525 Burst Disk Assembly - Retrofit kit for Oxidation Pressure Vessel without burst disk assembly
  • 250-000-22F ASTM 22F Thermometer - Range: 204 to 218°F
  • 250-000-22C ASTM 22C Thermometer - Range: 95 to 103°C
  • K10504-OPS 2-Unit System, 115V 60Hz
  • K10594-OPS 2-Unit System, 220-240V 50/60Hz
  • K10505-OPS 4-Unit System, 115V 60Hz
  • K10595-OPS 4-Unit System, 220-240V 50/60Hz
  • K10506-OPS 6-Unit System, 115V 60Hz
  • K10596-OPS 6-Unit System, 220-240V 50/60Hz
  • K10504-0-1 Transducer
  • K10570 One-Pen Recorder
  • K10580 Two-Pen Recorder
  • K10590 Pressure Gauge
  • 308-000-005 Recorder Charts - Pack of 100
  • 308-001-02R Recorder Cartridge Pen, Red (for use with K10570 Recorder)
  • 308-001-02B Recorder Cartridge Pen, Blue (for use with K10570 and K10580 Recorders)
  • 308-001-L2R Recorder Cartridge Pen, Long Red (for use with K10580 Recorder)

 

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Request a Quote
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot