Specification of

Description

Rapid Tester® provides rapid determinations of flash point or sustained burning qualities by using a small sample. A flash/no flash test result is achieved in one minute for flash points below 212°F (100°C) with a 2mL sample. Ideally suited for quality assurance and environmental compliance testing as well as actual flash point for paints, fragrances, hydrocarbons and other liquids. Open cup models are used for determining sustained burning qualities characteristics of mixtures of flammable and nonflammable liquids or liquids with widely different flash points when assessing flammability characteristics. Features convenient semi-automatic operation for flash/no flash tests. Set the test temperature on the digital display and inject a 2mL or 4mL sample into the sample cup. The tester quickly stabilizes itself at the desired value, permitting the test flame to be applied and the result to be observed by the operator. Unit also performs conventional determinations of actual flash temperature by the small scale closed tester method. The Closed Cup Model is for routine flash point tests in the range from –30 to +300°C (–22 to +572°F).

Test Method

Verifies the flash point or the sustained burning qualities of small samples in the range of –30°C to +300°C.

Features

  • Conforms to ASTM D3278, D3828; DOT CFR 49-173.115; IATA;
  • ISO 9038, BS3900 Part A11, A13, A14 and related specifications
  • One minute test with a 2mL sample
  • Simple to operate

Specification

Conforms to the specifications of: ASTM D3278, D3828; IP 303; ISO 3679, ISO 3680, ISO 9038; DOT CFR 49-173.115; IATA

Additional Accessories

  • K16506 Fuel Cylinder Valve
  • K16507 Heat Transfer Compound for thermometer
  • K16508 Metal Cooling Block to facilitate cooling of the sample cup between tests
  • K16509 Refrigerant Charged Cooling Block to hold cooling mixture for subambient testing
  • K16510 Syringe 2mL/4mL
  • K16511 Thermometer, range 32 to 572°F/0 to 300°C
  • K16512 Thermometer, range 32 to 230°F
  • K16513 Thermometer, range 212 to 572°F
  • K16514 Thermometer, range 0 to 110°C
  • K16515 Thermometer, range 100 to 300°C
  • K16516 Thermometer, range –36 to +105°F
  • K16517 Thermometer, range –38 to +40°C

Included Accessories

  • Thermometer, range 32 to 572°F (0 to 300°C)
  • Syringe

Electrical Requirements

115V 60Hz
220-240V 50/60Hz

 

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Request a Quote
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot