sql

Koehler K18919 Oil Separation Apparatus - Constant Temperature Air Cabinet

Rp. CALL
Last Updated
21 Sep 2021
Country Origin
United States
Minimum Order
1 unit
Category
KOEHLER

Specification of Koehler K18919 Oil Separation Apparatus - Constant Temperature Air Cabinet

Specification


Conforms to the specifications of: 


ASTM D1742, FTM 791-322


Capacity: four samples


Controller Sensitivity: ±1°F (±0.5°C)


Features



  • Conforms to ASTM D1742 and related specifications

  • Four sample capability

  • Controls temperature and air pressure


Test Method


Determines the tendency of lubricating grease to separate oil during storage in a 35 lb pail. The sample is placed on a sieve inside a special test cell and subjected to 0.25psi (1.72kPa) air pressure at constant temperature. Any oil that bleeds from the grease during a 24 hour period is collected in the cell and weighed.


Description


Consists of pressure bleeding test cells with air pressure regulation system and constant temperature air cabinet. Pressure Bleeding Test Cell–Type A test cell includes cup assembly with funnel and positioning seat for beaker; cover with air inlet fitting; and 200-mesh stainless steel sieve strainer with brass support ring. Bayonet type connection and o-ring seal provide tight closure between cover and base. Cup, funnel and base are constructed of chrome plated spun copper. Order test beaker separately. Constant Temperature Air Cabinet–Provides a constant temperature  environment and regulated air pressure per ASTM specifications. Consists of an insulated airtight cabinet with pressure system to accommodate four pressure bleeding test cells. Equipped with electric heater, solid state controller, cooling coil and circulating fan for efficient temperature control at 77°F (25°C). Pressure system includes air inlet pressure regulator with gauge, cartesian manostat, manifold with control valves for four test cells, output gauge, manostat and gas washing bottle. Built-in pressure relief valve protects against pressure surge. Cabinet is constructed of double-wall stainless steel with full insulation. Order thermometer and pressure bleeding test cell separately.


Additional Accessories



  • K18900 Pressure Bleeding Test Cell

  • 332-002-009 Test Beaker, 20mL 

  • 250-000-57F ASTM 57F Thermometer. Range: –4 to +122°F 

  • 250-000-57C ASTM 57C Thermometer. Range: –20 to +50°C


Electrical Requirements


115V 60Hz, Single Phase, 3A

220-240V 50/60Hz, Single Phase, 1.5A


 


 


Lihat Selengkapnya

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Request a Quote
Produk Siap di Pesan
Rp 0
1