Description

Constant temperature bath rotates oxidation pressure vessels at 100rpm at an angle of 30° in accordance with ASTM specifications. Includes drive system and oil bath with electronic solid state temperature control. Meets ASTM requirements for heat transfer capability and temperature control precision. A convenient carriage arrangement allows the oxidation vessels to be inserted quickly and securely in the drive system. A strong magnet holds the vessel in place while locating pins in the carriage engage the base of the vessel. PTFE guides support the pressure vessel stem for added stability. If the vessel becomes obstructed for any reason, the magnetic carriage releases it to prevent damage. A chain and sprocket drive system powered by a heavy duty capacitor start motor rotates the vessel carriages at 100rpm. Drive shafts ride on PTFE fluorocarbon bearings which provide extended service and are compatible with silicone heat transfer fluids and other types of bath oils.

Test Method

The RPVOT (RBOT) procedure employs severe oxidation conditions to rapidly determine oxidation stability. Suitable for both new and in-service oils, the RPVOT (RBOT) method is applicable to many types of petroleum oils. The sample is oxidized in the presence of water and a copper catalyst in a stainless steel pressure vessel under an initial pressure of 90psi (620kPa). Pressure inside the vessel is recorded electronically or mechanically while the vessel is rotated at 100rpm at constant temperature, and the amount of time required for a specified drop in pressure is the oxidation stability of the sample. A variation of the RPVOT (RBOT) method is the “Thin Film Oxidation Uptake Test” (TFOUT) for gasoline automotive engine oils.

Features

  • 2, 3 and 4-unit systems
  • Oxidata® Pressure Measurement System
  • Conforms to ASTM D2112, D2272 and IP 229 specifications for RPVOT (RBOT) testing
  • Conforms to ASTM D4742 specifications for TFOUT testing

Specification

Conforms to the specifications of: ASTM D2112, D2272, D4742; IP 229

Capacity: 2, 3 or 4 oxidation pressure vessels

Temperature Control:

 

Maximum Temperature: 200°C (392°F)
Control Stability: ±0.02°C (±0.04°F)

Heater Range:

2 and 3-pressure vessel models: 0-2750W
4-pressure vessel models: 0-3750W

Recommended Bath Medium: high temperature silicone heat transfer fluid 
Drive System: 100rpm positive drive transmission powered by a continuous duty 1⁄2hp ball bearing motor with built-in gear reducer

Bath Capacity:

K70200/K70290 18gal (68L)
K70300/ K70390 25gal (95L)
K70400/ K70490 32gal (121L)

Capacity:

K70200/K70290 2 oxidation vessels
K70300/ K70390 3 oxidation vessels
K70400/ K70490 4 oxidation vessels

Additional Accessories

  • K70000 Oxidation Pressure Vessel
  • K70092 Aluminum Insert - Converts standard K70000 Oxidation Pressure Vessel for use in the TFOUT method

RBOT/TFOUT Oxidata Pressure Measurement System

  • K70502-XP Two-Unit System, 115V 60Hz
  • K70592-XP Two-Unit System, 220-240V 50/60Hz
  • K70503-XP Three-Unit System, 115V 60Hz
  • K70593-XP Three-Unit System, 220-240V 50/60Hz
  • K70504-XP Four-Unit System, 115V 60Hz
  • K70594-XP Four-Unit System, 220-240V 50/60Hz

Sample Beakers

  • K70040 RPVOT (RBOT) Sample Beaker Borosilicate glass, 175mL. Meets ASTM D2112, D2272 specifications
  • K70091 TFOUT Sample Container Borosilicate glass. Meets ASTM D4742 specifications

Oxygen Charging Accessories

  • K70080 Charging Hose. 6 ft (1.8m), with connections
  • K70082 Female Quick Disconnect Coupling, for charging hose
  • K70081-1 Male Quick Disconnect Coupling, 1⁄4" NPT, for oxidation pressure vessel
  • K70013 Oxygen Pressure Regulator

Oxidation Pressure Vessel Accessories

  • K70050 Silicone O-ring - Replacement seal for pressure vessel lid-body connection
  • K70049 Sample Beaker Cover (PTFE disk)
  • K70048 TFOUT Sample Beaker Cover (PTFE disk)
  • K70000-03008 Spring. Inserts in pressure vessel to hold RPVOT (RBOT) beaker and cover in place
  • K700-0-3A Spring. Inserts in pressure vessel to hold TFOUT container and cover in place

Copper Catalyst for RPVOT (RBOT) Method

  • K70030 Copper Catalyst Coil Prepared in accordance with ASTM specifications and packed in a sealed glass container with nitrogen atmosphere. Ready to use.
  • K70090 Copper Catalyst Wire - 1.63mm electrolytic copper wire in 500 ft (152m) lengths.
  • K70002 Winding Mandrel - Machined aluminum mandrel for winding copper wire into coils meeting ASTM specifications. Mounts on K70003/K70004 Drive Unit
  • K70003 Drive Unit for Winding Mandrel - Slow speed gear motor mounted on a sturdy base. Facilitates coil winding procedure. 115V
  • K70004 Drive Unit for Winding Mandrel - Similar to K70003 but for operation on 220-240V

Catalyst Package for TFOUT Method

  • K70093 Catalyst Package A - For simulating IIID engine test. Includes 3 catalyst packages
  • K70095 Catalyst Package B - For simulating IIIE engine test. Includes 3 catalyst packages

Pressure Vessel Support Racks

  • K70017 Pressure Vessel Support Rack, 2-Unit
  • K70011 Pressure Vessel Support Rack, 3-Unit
  • K70012 Pressure Vessel Support Rack, 4-Unit

Pressure Recording Equipment

  • K70010/24 Pressure Recorder, 24-hour
  • K70018 Replacement Cartridge Pen

Thermometers

  • 250-001-37C IP 37C Thermometer. Range: 144 to 156°C - For RPVOT (RBOT) method.
  • 250-000-96C ASTM 96C Thermometer. Range: 120 to 150°C - For ASTM D2112 method.
  • 250-000-100C ASTM 100C Thermometer. Range: 145 to 205°C - For TFOUT method.

Electrical Requirements

115V 60Hz, Single Phase, 10.2A
220-240V 50/60Hz, Single Phase, 5.3A

 

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Request a Quote
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot