sql

AEMC PEL 102 - Power and Energy Logger w/o Sensors

Rp. 100
Last Updated
02 May 2023
Minimum Order
1 Unit
Category
AEMC

Specification of AEMC PEL 102 - Power and Energy Logger w/o Sensors

AEMC PEL 102 - Power and Energy Logger w/o Sensors

Catalog 2137.61

Power and Energy Logger Model PEL 102 (No LCD, No Sensors) {ETL}

Power & Energy Logger Model PEL 102 (no LCD)

Power/Energy data logging for 50Hz, 60Hz, and 400Hz and DC distribution systems

USB, LAN, and Bluetooth communication

17 types of supported hook-ups or electrical distribution systems

All in one kit, including (3) 3,000A mini-flex probes (3in diameter)

Economical Compact Simple To Use

Inputs 3 Voltage / 3 Current: calculation of neutral current
Sample Rate128 per Cycle6.4kHz at 50Hz7.68kHz at 60Hz
SpecificationRangeMeasurement RangeResolutionAccuracy (Typical)
Volt
Vrms1000V P to N10  to 1000V0.1V±0.2% Rdg + 0.2V
Urms1000V P to P17 to 1700V0.1V±0.2% Rdg + 0.4V
Amps @ 50 and 60Hz
Amps (1V nominal)
(excluding clamp accuracy
Probe dependent0.2%< I < 120% InomProbe dependent±0.2% Rdg + 0.02% Inom
AmpFlex & MiniFlex 
(including sensor accuracy)
Range 100A 
Range 400A
Range 2kA
Range 10kA
200mA to 120A
5 to 440A
50 to 2400A
400A to 12kA
1mA
0.1A
0.1A & 1A
1A
±1.2% Rdg + 50mA
±1.2% Rdg + 0.2A
±1.2% Rdg + 1A
±1.2% Rdg + 5A
Frequency 42.5 to 69Hz0.01Hz±0.1Hz
Power
Watts (VA, var) P-Q-S10W to 10GW / 10var to 10Gvar / 10VA to 10GVA4 digits min±0.5% Rdg + 0.005% Pnom
Power Factor (Cos Φ/DPF)-1  to 10.001±0.05
Energy
kWh (kVAh, kvarh) P-Q-SUp to 4EWh / 4Evarh / 4 EVAh (E = 1018 )±0.5% Rdg
HarmonicsDC, 1 to 50
Volts & Amp % 0.01 to 655.0%0.01%±1% Rdg from 1 to 25
THD 0.00 to 655.0%0.01%±1% Rdg
General Features
CaseDesign Rugged, shock proof with integrated protective holster, IP54 not included terminals. Shock and vibration IEC61010
InterfaceIsolated USB, Bluetooth, and Ethernet, SD card for direct transfer to PC. Dataview software for real time data, configuration and reporting included
Memory8GB SD card (SDHC compliant, FAT32 formatted)  32GB max
DisplayNone
Real-Time ClockTime and date stamp for Trend mode
PowerAC 110V/230V 50/60Hz 15VA; Battery backup when power OFF, 60 minutes typical
Dimensions
(L x W x H)
10.08 x 4.92 x 1.46” (256 x 125 x 37mm)
Weight2.2 lbs (1kg)
Altitude Operating2000m (6560ft)
Operating Temperature32° to 108.5°F; (0° to +42.5°C) from 10 to 85% RH
Storage Temperature-4° to 122°F; (-20° to +50°C) from 0 to 75% RH with battery pack
Electro-Magnetic-Compatibility (EMC)EN 61326-1 for emission and immunity
IP RatingIP54 per IEC 60529
SafetyIEC/EN 61010-1 (1000V CAT III-600V CAT IV), IEC 1326-1

In The Box

  • Small Classic Tool Bag
  • 5ft USB Cable
  • (4) 10ft Black Voltage Leads and Alligator Clips
  • Power Cord
  • (12) Color-Coded ID Markers
  • MultiFix Mounting System
  • Safety Card for the PEL
  • 8.4V NiMH Battery
  • Sensor Compliance Sheet
  • 8GB SD-Card with USB SD-Card Reader
  • Quick Start User Guide
  • USB Drive Supplied with DataView Software
  • User manual